CTEC CFP Alarmsense Conventional 8 zone panel Two Wire CFP708-2
- Brand: CTEC
- Product Code: CFP708-2
- Availability: 3-5 Days
£278.92 Inc VAT £232.43 Ex VAT
CTEC CFP AlarmSense Conventional 8 zone panel (Two Wire)
CFP Alarmsense 8 zone, two-wire fire panel.
The CFP708-2 includes four AlarmSense zones, four conventional sounder circuits, class change & alert inputs and onboard fire & fault relays.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities.
Includes 8 AlarmSense zone circuits.
Note: requires 2 x 3.4Ah lead acid batteries.
For use only with Apollo AlarmSense two-wire detectors, call points and sounders.
Approvals/certifications                          Certified to EN54-2/4 by the LPCB (0832-CPR-F0386).
Mains supply                                             230V 50/60Hz.
Mains rated current                                 350mA maximum.
Internal power supply                             19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to              1.5A @ 230Vac (ImaxA eq 146mA).
Quiescent current                                     25mA (mains failed, internal sounder active, PSU & gen fault LED lit).
Max battery size and type                       2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah.
No. of detector zone circuits                   The CFP708-2 has 8 AlarmSense zone circuits which are compatible with Apollo's AlarmSense range of detectors & call points AND sounders & visual indicators. 
Call point resistor value                           Only use AlarmSense call points.
Max. devices per detector zone              25 AlarmSense detectors/manual call points per AlarmSense zone. 
No. of conventional sounder circuits     4 - these are additional conventional (non-AlarmSense) sounder circuits; Max. length per circuit is 500m.
EOL resistor value                                     6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Alarm voltage                                             27V max, 20V min (final battery voltage)
Max. sounder output current                  Each AlarmSense zone circuit & sounder circuit will support a max. sounder current of 200mA. Total sounder loading per panel should not exceed 1.25A.
Expansion connections                            Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards.
Product dimensions (mm)                       380 W x 235 H x D 96mm.
Construction & finish                                Plastic lid and base; RAL7035 textured
IP Rating                                                      IP30
Weight                                                         1.75kg (without batteries).

 
        