Call Us: 01707 802233

Default welcome msg!

Categories

  • Categories
  • Battery
  • Heat Alarm
  • Smoke Alarm
  • Electrical
  • Induction Loop Kits
  • Power Supply Units
  • Plugs and Sockets
  • Fire Safety
  • Carbon Monoxide Alarms
  • Battery CO Alarms
  • Mains CO Alarms
  • Test Kits
  • Smoke and Heat alarms
  • Mains smoke alarms
  • Mains heat alarms
  • Battery smoke alarms
  • Battery heat alarms
  • Testing kits
  • Accessories
  • Fire Alarm Systems
  • Two Wire Conventional
  • Four Wire Conventional
  • Addressable
  • Fire Extinguishers and Blankets
  • Blankets
  • Extinguishers
  • Home Safety
  • Lighting
  • Home Lighting
  • Bathroom Lighting
  • Display Lighting
  • Downlights
  • Fire Rated Downlights
  • Night Light
  • Vintage Lighting
  • Security
  • Exit Devices
  • Break Glass
  • Exit buttons
  • Wireless
  • Infrared
  • Firemans Switch
  • Evacuation Devices
  • Door Retaining Magnets
  • Refuge Systems
  • Nurse Call Systems
  • Disabled Persons Toilet Alarm Kits
  • 800 series
  • Quantec
  • Dementia Care
  • Vehicle Cameras
  • Your shopping cart is empty!

CTEC Standard Conventional 2 Zone Panel CFP702-4

  • Brand: CTEC
  • Product Code: CFP702-4
  • Availability: 3-5 Days

£133.27 Inc VAT £111.06 Ex VAT

CTEC Standard Conventional 2 Zone Panel

CFP Conventional 2 zone panel.

Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, onboard fire and fault relays and combined keypad/keyswitch entry.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.

LPCB certified to EN54-2/4.

Note: requires 2 x 12v 3.4AH lead acid batteries.


Approvals/certifications                                 Certified to EN54-2/4 by the LPCB (176b) / (0832-CPD-1704).
Mains supply                                                    230V 50/60Hz.
Mains rated current                                        350mA maximum.
Internal power supply                                    19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to                     1.5A @ 230Vac (ImaxA eq 146mA).
Quiescent current                                           25mA (mains failed, internal sounder active, PSU & gen fault LED lit).
Max battery size and type                              2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah.
No. of detector zone circuits                         2 (Max. length per circuit is 500m).
Call point resistor value                                 470 to 680Ω.
Max. devices per detector zone                   25 detectors (or 32 detectors/manual call points combined).
No. of conventional sounder circuits          4 (Max. length per circuit is 500m).
EOL resistor value                                           6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Alarm voltage                                                   27V max, 20V min (final battery voltage).
Max. sounder output current                       4 x 200mA (800mA total).
Expansion connections                                 Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards.
Product dimensions (mm)                            380 W x 235 H x D 96mm.
Construction & finish                                     Plastic lid and base; RAL7035 textured.
IP Rating                                                           IP30.
Weight                                                              1.75kg (without batteries).
Operating conditions/temperature             -5ºC to +40ºC. Max relative humidity: 95%.